Melux Control Gears Pvt. Ltd. Melux Control Gears Pvt. Ltd.
Home About Technical

Contact & Inquiries 

   
Electronic Ballasts for Compact Fluorescent Lamp - TCD
 
 
Features (In MELCON APFC models) :
Warm start - < 1.5 seconds.
THD < 10%
Constant lumen output
Power factor - 0.98+
Operating voltage - 145v to 270v.
   
Article No. Lamp
Wattage
Circuit
Power
Lamp
Power
Input
Voltage
Input
Current at 230v/50Hz
Power
Factor
Case Code Wiring
Diagram
Code
CFL - TCD
MCMP109 1 X 9 10.0 7.8 230 0.065 0.65 C1 A
MCMP110 1 X 10 12.0  8.3 230  0.068 0.65 C1 A
MCMP111 1 X 11 14.0 11.8 230 0.095 0.65 C1 A
MCMP113 1 X 13 15.0 12.6 230 0.098 0.65 C1 A
MCMP118 1 X 18 19.0 16.5 230 0.13 0.65 C1 A
MCSP209 2 X 9 20.0 2 X 7.9 230 0.09 0.9 C2 B
MCSP211 2 X 11 24.0 2 X 10 230 0.115 0.9 C2 B
MCSA109 1 X 9 12.0 8.0 230 0.05 0.96 C2 A
MCSA209 2 X 9 21.0 2 X 8 230 0.10 0.96 C2 B
MCSA111 1 X 11 14.0 10.0 230 0.06 0.96 C2 A
MCSA211 2 X 11 26.0 2 X 10 230 0.12 0.96 C2 B
MCDP210 2 X 10 22.5 2 X 9 230 0.10 0.96 C2 B
MCDP213 2 X 13 28.0 2 X 12 230 0.125 0.96 C2 B
MCDP218 2 X 18 38.0 2 X 16.5 230 0.14 0.96 C2 B
MCDP126 1 X 26 27.8 24.0 230 0.13 0.96 C2 A
MCDP226 2 X 26 54.0 2 X 23.5 230 0.23 0.96 C2 B
MCDA110 1 X 10 13.0 1 X 8 230 0.06 0.98 C2 A
MCDA210 2 X 10 24.0 2 X 8 230 0.10 0.98 C2 B
MCDA113 1 X 13 17.0 1 X 12 230 0.07 0.98 C2 A
MCDA213 2 X 13 30.0 2 X 12 230 0.11 0.98  C2 B
MCDA118 1 X 18 21.0 1 X 16 230 0.09 0.99 C2 A
MCDA218 2 X 18 40.0 2 X 16 230 0.14 0.98  C2 B
MCDA126 1 X 26 29.0 1 X 24 230 0.13 0.99 C2 A
MCDA226 2 X 26 56.0 2 X 24  230 0.235 0.99 C2 B
CFL - TCT
MCTP118 1 X 18 22 18  230 0.08  0.96 C2  
MCTP218 2 X 18 44.5 2 X 18 230 0.16 0.96 C2
MCTP126 1 X 26 29 25.5 230 0.12 0.96 C2
MCTP226 2 X 26 56 2 X 25.5 230 0.24 0.96 C2
MCTP132 1 X 32 35 31.5 230 0.15 0.96 C2
MCTP232 2 X 32 71 2 X 31.5 230 0.31 0.96 C2
MCTP142 1 X 42 46 41.2 230 0.20 0.96 C2
MCTA118 1 X 18 24 18 230 0.10 0.99 C2
MCTA218 2 X 18 45 36 230 0.16 0.99 C2
MCTA126 1 X 26 30 26 230 0.13 0.99 C2
MCTA226 2 X 26 56 52 230 0.13 0.99 C2
MCTA132 1 X 32 36 32 230 0.26 0.99 C2
MCTA232 2 X 32 71 64 230 0.32 0.99 C2
MCTA142 1 X 42 45.5 41 230 0.21 0.99 C2

Though the emergency ballast is for twin lamp, emergency operation will be for single lamp only.